EPD Electromagnetic Flow Meter
The ery FIRST Electromagnetic flow meter (EPD) to be certified by OIML in Asia
EPD30 offers the industry’s widest range of liners, electrodes and sizes to meet the needs of even the most demanding process applications in sectors as diverse as chemical, power, oil & gas and metals & mining. The powerful transmitter is easy to use and provides the output signal that meets your needs. With EPD30 you get a versatile, reasonably priced, most accurate flow meter tailored for your applications. A flowmeter with base functionality, short delivery and a simple and clearly understandable documentation.
Thông tin chi tiết
Model : EPD30-100-N5ENJ2F0
Có sẵn :
1
Model : EPD34-050-N5ENJ2F0
Có sẵn :
1
Khuyến Mại :
Phòng thí nghiệm đo lưu lượng của FineTek đã nhận được chứng nhận từ Taiwan Accreditation Foundation và tuân thủ các quy định của các tổ chức quốc tế như ILAC và APALC.
Giới thiệu
Tính năng
Ứng dụng
Giới thiệu
The working principle of the electromagnetic flow meter is based on the Faraday law of electromagnetic induction. When the conducting liquid flows in the orthogonal direction of the magnetic line direction, it will cut the magnetic lines and generate induced voltage, which shows linear relationship with the flowing speed. Thus, the fluidic volume flow can be calculated.
EPD electromagnetic flow meter is mainly composed of the sensor and transmitter. The measuring tube of the sensor is equipped with the excitation coils upward and downward. The transmitter supplies the excitation current, which generates the magnetic field which goes through the measuring tube once it is powered on. A pair of induction electrodes installed on the inner side of the measuring tube comes in contact with the liquid to guide the induced voltage to the sensor.
Tính năng
- Measurement is virtually independent of density, viscosity, temperature, pressure and conductivity.
- Two measuring points inside tube and no moving parts to prevent pressure losses and pipe blockage.
- Electric conductive liquid and fluids with low solid contents can also be measured.
- Simple piping design: straight zone of the pipe for installation requests upstream 5D and downstream 2D.
- With self diagnosis function to check magnetizing signal, empty pipe and contaminated electrode.
Ứng dụng
- Accuracy: 0.3%、0.5%、1.0%
- Flow range: 0.1~10 m/s
- Current output: 4-20mA/700Ω
- Pulse output: NPN / 200mA/32Vdc maximum
- Alarm output: NPN / 50mA/32Vdc maximum
- Communication Interface: RS-485 Modbus
- Measurable flow range